Thermal noise-limited beam balance as prototype of the Archimedes vacuum weight experiment and B-L dark photon search
Annalisa Allocca · Saverio Avino · Enrico Calloni · Sergio Caprara · Massimo Carpinelli · Andrea Contu · Luca D’Onofrio · Domenico D’Urso · Rosario De Rosa · L. Errico · Marina Esposito · Gianluca Gagliardi · Marco Grilli · Valentina Mangano · Maria Marsella · Luca Naticchioni · Antonio Pasqualetti · Gianpiero Pepe · Maurizio Perciballi · Paola Puppo · Piero Rapagnani · Fulvio Ricci · Luigi Rosa · Carlo Rovelli · Davide Rozza · Paolo Ruggi · Naurang L. Saini · Valeria Sequino · Valeria Sipala · Daniela Stornaiuolo · Francesco Tafuri · Lucia Trozzo
Open licence · full text · Creative Commons Attribution 4.0 International (CC BY 4.0)
In one page
Vacuum energy is the largest arithmetic mismatch in physics: quantum mechanics fills empty space with an enormous energy density, while the observed expansion of the universe says the part that gravitates is minute. The Archimedes collaboration, led from Naples by Enrico Calloni and including Carlo Rovelli, proposes to settle a piece of that by weighing it. The plan is to hang a high-temperature superconductor from a balance arm and cycle it through its transition temperature, because the electromagnetic vacuum energy inside the sample changes at the transition — so if that energy has weight, the balance tips, by a few times ten to the minus sixteen newtons. This paper reports the prototype: a half-metre aluminium arm, read by a Michelson interferometer, running closed-loop in the seismically quiet Sos Enattos mine in Sardinia. It reaches a torque noise of about seven times ten to the minus thirteen newton-metres per root hertz — its own suspension’s thermal limit, exactly the level the final cryogenic balance was designed around. The same dissimilar-metal balance also sets first limits on ultralight dark photons.
Why it matters hereChapter 2 says the vacuum is a real medium with a real energy density; chapter 3 says that energy is what gravity and inertia are made of. This is the experiment that puts a number on the join — a laboratory balance that asks whether a change in vacuum energy has weight — and chapter 1 cares that the prototype has already hit its designed noise floor, which turns the final measurement from a hope into a schedule.
What it claims
01The deepest open problem in the field is the cosmological one: the enormous vacuum energy density quantum mechanics attributes to empty space cannot be reconciled with the very much smaller cosmological constant the universe actually shows when that energy is inserted into Einstein’s equations. The Archimedes experiment attacks it experimentally rather than theoretically, by measuring how vacuum fluctuations interact with gravity.Sect. 1, Introduction, opening paragraph
What to watch02The Archimedes method is to weigh the change in vacuum energy content at the superconducting transition of a high-temperature superconductor sample of about 0.2 kg. The final apparatus is a cryogenic balance working near 90 K, modulated around the transition temperature of GdBCO, and the weight variation expected is of the order of a few times 10⁻¹⁶ N at a modulation frequency of about 10 mHz.Sect. 1, Introduction, second paragraph
Designed, not yet built03The room-temperature prototype reaches a torque noise of about 2 times 10⁻¹² Nm per root hertz at 10 mHz, falling to about 7 times 10⁻¹³ Nm per root hertz at around 60 mHz, corresponding to a force sensitivity of about 3 times 10⁻¹² N per root hertz. Between roughly 20 mHz and 100 mHz the measured spectrum is compatible with the thermal noise of the suspension itself, computed from the measured quality factor Q of 90 and the restoring constant of the 26 mHz resonance.Abstract; Sect. 3, Eq. (1) and Fig. 5
Published and peer-reviewed04Reaching the thermal noise floor demonstrates that the optical and mechanical design is correct: the interferometric read-out, the nested closed loop with thermal actuators below the mHz and electrostatic actuators above it, and the choice of the extremely quiet Sos Enattos site all work as designed. The final balance needs a torque noise below 10⁻¹³ Nm per root hertz around 10 mHz on a 1.4 m arm, to be won from cryogenic operation at 77 K, a 5 mHz resonance, a moment of inertia of 0.3 kg m², and an improved suspension quality factor, with an integration time of order 10⁶ seconds — about two weeks.Sect. 1; Sect. 2; Sect. 3, Eq. (2) and Fig. 6
Designed, not yet built05Because the balance carries a weight and a counterweight made of different materials — aluminium against lead — it is sensitive to an ultralight dark photon coupled to the B minus L current, which would drive an almost monochromatic force on the two masses in proportion to their differing neutron numbers. A first very short run of 21000 s already sets a limit on the B minus L coupling close to the standing limits from the EOT-WASH and MICROSCOPE free-fall experiments, in a frequency band from about 20 mHz to 200 mHz that direct searches have not yet covered.Sect. 4, Eqs. (4) and (7); Fig. 7
On the bench now06The named next measurements are the first scientific runs of the prototype, dedicated to a direct search for the B minus L dark photon in a mass band about a decade wide around 10⁻¹⁶ eV, taken during the mine’s holiday periods and with the remaining fan-cooled instruments removed; months of integration would be enough to overtake the current best limits. In parallel the collaboration is studying the suspension losses of the copper-beryllium joints, and other materials, for the cryogenic balance.Sect. 5, Discussion and future developments
What to watch
Read it
Abstract
We describe the behavior of a beam balance used for the measurement of small forces, in macroscopic samples, in tens of mHz frequency band. The balance, which works at room temperature, is the prototype of the cryogenic balance of the Archimedes experiment, aimed at measuring the interaction between electromagnetic vacuum fluctuations and the gravitational field. The balance described has a 50-cm aluminum arm and suspends an aluminum sample of 0.2 Kg and a lead counterweight. The read-out is interferometric, and the balance works in closed loop. It is installed in the low seismic noise laboratory of SAR-GRAV (Sardinia — Italy). Thanks to the low sensing and actuation noise and finally thanks to the low environmental noise, the sensitivity in torque τ̃n is about τ̃n ≈ 2 × 10⁻¹² Nm/√Hz at 10 mHz and reaches a minimum of about τ̃n ≈ 7 × 10⁻¹³ Nm/√Hz at tens of mHz, corresponding to the force sensitivity F̃n of F̃n ≈ 3 × 10⁻¹² N/√Hz. The achievement of this sensitivity, which turns out to be compatible with thermal noise estimation, on the one hand, demonstrates the correctness of the optical and mechanical design and on the other paves the way to the completion of the final balance. Furthermore, since the balance is equipped with weight and counterweight made of different materials, it is sensitive to the interaction with dark B-L photons. A first very short run made to evaluate constraints on B-L dark photon coupling shows encouraging results that will be discussed in view of next future scientific runs.
1. Introduction
One of the deepest problems of contemporary physics is the "cosmological problem" or rather the impossibility of reconciling the enormous value that quantum mechanics attributes to vacuum energy with the observation that the universe shows a value of cosmological constant enormously smaller than estimated by inserting this vacuum energy into Einstein's equations.
In this context, we recently started the Archimedes experiment aimed at measuring the interaction of vacuum fluctuations with gravity. The experimental method is the measure of a change in weight due to the change in vacuum energy content at the transition of a high-Tc superconductor (with a mass of approximately 0.2 kg). The experimental apparatus will be a cryogenic balance, working at a temperature of about 90 K, modulating it around the transition temperature of the superconductor (GdBCO). The amplitude of the weight variations is expected to be of the order of few 10⁻¹⁶ N modulated at a frequency of about 10 mHz.
Driven by the fact that the balance must be extremely sensitive, we realized a prototype intended above all to identify any experimental difficulties and develop the experimental techniques necessary for the final balance. The goal of the prototype is to reach a torque sensitivity τ̃n, on an arm of half a meter, of the order (or better) of 10⁻¹² Nm/√Hz that could pave the way toward the final measurement, in which a sensitivity balance better than 10⁻¹³ Nm/√Hz is required, with a balance arm 1.4 m long, so to detect the signal in an integration time of the order of 10⁶ s (about 2 weeks).
The prototype works at room temperature and shares with the final balance several critical features: the read-out of the arm tilt is interferometric, the balance works in closed loop, and it is installed in a very seismically quiet site, in the region of Sardinia (Italy).
The initial version of the prototype was presented in previous papers: having not suspended samples at its arm, it was tested, in particular, as ground tilt sensor, showing a remarkable sensitivity.
Currently, the prototype has been equipped with a suspended sample with a mass of 0.2 kg, which mimics the final balance sample. With respect to previous works, the prototype has been also isolated from almost all possible sources of laboratory noise, and finally, the loop has been optimized by adding a temperature actuator that improved both the sensitivity and the lock duration.
The set of these improvements, which will be described and discussed in the rest of the article, led to the achievement of a sensitivity compatible with thermal noise, with a noise torque of the order (or slightly better) of 10⁻¹² Nm/√Hz in the band of tens of mHz.
These achievements on the prototype constitute a solid step toward the final Archimedes balance: in particular, they demonstrate the robustness and sensitivity of the interferometric reading, of the control system, and the usefulness of carrying out the experiment in a very quiet site from a seismic point of view. Furthermore, we equipped the prototype with a weight and counterweight of different materials, to check what limits could be reached by this balance in the direct search of dark matter in the form of ultralight dark photon B-L, i.e., an ultra-light boson mass (ULBM) vector that couples with the B-L charge, being B the number of Baryons and L the number of Leptons.
In fact, among all possible dark matter candidates, recent attention has been posed in the search for bosonic ultralight fields with masses presently bounded in lower limits m greater than or equal to 10⁻²² eV and extending up to order of the eV.
Relevant in recent years has been the experimental research in the region of extremely low masses, on the order of m ≈ 10⁻¹¹ eV or less. Important constraints on the coupling of dark photons are reached through equivalent principle tests with EOT-WASH and MICROSCOPE experiments.
On the other hand, new constraints on dark photon coupling have been reached through direct search: the background of ultralight dark photons is expected to generate time-dependent forces on bodies, almost monochromatic, which in principle can be detected by measuring the spectrum of the position of a suspended body and searching for an almost monochromatic noise at the frequency f ≈ m_A c²/h of the dark photon field. This has prompted the dark photon direct search with very high-precision interferometry, particularly with gravitational-wave interferometers, such as LIGO, Virgo, GEO, and Kagra.
LIGO and Virgo, although not detecting any signal attributable to dark photons, have imposed remarkably stringent limits on the value of the coupling constant (both B coupled and B-L coupled dark photons) in the frequency region from a few kHz down to 10 Hz, corresponding to the mass region of order 10⁻¹⁴ to 10⁻¹¹ eV, under the hypothesis that the whole dark matter mass is due to this particle. In a lower part of the frequency spectrum, the mHz, corresponding to the masses around f ≈ 10⁻¹⁸ eV, direct search with torsion pendulums has led to new limits in B-L coupled dark photons. With respect to these experiments, our balance can cover a frequency bandwidth not yet explored in direct search, in particular in the region from 20 mHz to 200 mHz (and above with lower sensitivity), corresponding to a mass decade above m_A ≈ 10⁻¹⁶ eV. In the last part of the paper, we will show and discuss limits on the B-L dark photon coupling obtained with a short measurement run carried out with the present prototype. These limits are not yet more stringent than those obtained with the free fall experiments, but with a few months of integration time, a data taking with the prototype could close the gap and lead to a first direct search.
2. The experimental apparatus
The experimental apparatus consists of a beam balance suspended with thin metallic joints, in a similar way to a rotation sensor originally realized by Venkateswara et al. Unlike the rotation sensor of Venkateswara (which has no additional suspended elements), our balance has a suspended element at one end of the arm, corresponding to the element in blue in Fig. 1. The length of the suspension wires is approximately 8 cm, compatible with the available space, and the wires are attached at the top in the vertical center of mass of the arm and at the bottom in the center of mass of the sample. This element mimics the similar suspended element of the final balance and is inserted to verify mainly the stability of the control loops and the sensitivity of the balance in this condition: the mass is 180 gr, very similar to the mass planned for the superconducting sample in the final experiment. On the same side of the arm balance, other aluminum weights for equilibrium tuning are installed. On the other side of the arm, a counterweight of lead is installed, sketched in yellow in Fig. 1, with its center of mass near the edge of the arm, actually at a distance of 0.24 m from the rotation center, with a mass of 0.210 kg. The balance arm is 0.5 m long, made of aluminum, and the total moment of inertia I ≈ 2.6 × 10⁻² kg m². The resonance frequency is f₀ ≈ 26 mHz in this measurement. The angular read-out is interferometric, through an equal-arms Michelson interferometer read in DC on the middle fringe, according to the scheme shown in Fig. 1 and also in the picture of Fig. 2. The apparatus is located in the site of Sos Enattos (Sardinia — Italy) to benefit from the extremely low seismic noise.
Fig. 1 — Scheme of the balance prototype including the optical read-out and the aluminum suspended sample (in blue) and the brass counterweight (in orange).
Fig. 2 — Picture of the balance. The red line shows the interferometer light path; the suspended sample is visible on the right end of the balance arm. The counterweight is not visible because it is embedded in the balance arm.
Fig. 3 — Scheme of the control feedback. The low-passed control signal of the interferometer is sent to thermal actuators.
The beam balance works in closed loop to keep the interferometer at the working point. Data are acquired, filtered, and sent to the actuators by a National Instruments C-RIO ADC/CPU/DAC system, acquiring data at 25 kHz and re-sampling them at 1 kHz before the filtering operations. The feedback loop corrects drifts in very low frequency, on the time scale of hours, mainly due to temperature drifts, and corrects the small angular fluctuations above the mHz. The feedback is a nested loop, also shown in Fig. 3: the control signal is sent to thermal actuators that act on the temperature of the chamber (covering the very low frequency range) and to electrostatic actuators that act directly on the beam balance arm and cover the frequency range above the mHz. In this way, the DC voltage sent to electrostatic actuators is reduced and the noise re-injected by electrostatic actuators in the interesting measurement band above 10 mHz, which is proportional to the DC voltage, is reduced to a negligible level.
The control signal, sent to electrostatic actuators, is calibrated with a 3-Hz injected line (more than one decade above the unity gain): the coupling constant α of applied voltage to torque on the balance is α ≈ 3.4 × 10⁻⁸ Nm/V. The open-loop transfer function is reported in Fig. 4. The unity gain of the loop is set at 140 mHz. At 1.65 Hz and 2.3 Hz, two notches are visible, used to limit the resonant oscillations of the suspended sample. The torque sensitivity τn is evaluated by acquiring the control signal sent to electrostatic actuators and corrected by the closed-loop transfer function, in which the corrected torque signal is multiplied by the factor GH/(1+GH), where H is the plant transfer function and G the correction filter transfer function. The signal τcorr is the voltage applied to electrostatic actuators multiplied by the constant α.
Fig. 4 — Bode plot of the control loop.
3. Results on the sensitivity and perspective for the Archimedes experiment
The results we report correspond to an initial run. The total science mode time is 21000 s, selected in the night time. The reason for not having longer data taking is that the prototype balance is located in a section of the laboratory that is not thermally stabilized (fans thermalization is not usable in science mode because it is noisy due to the fans) and located in a peripheral part of the building so that there are considerable temperature fluctuations that cannot all be compensated for by the balance's thermalization system. In addition, the hall is shared with the workshop operations still in place at the mine, and this severely limits the possibility of taking data during the day. In the immediate future, as will be discussed later, we plan to make other runs to study and eventually increase the sensitivity during working holiday periods of the mine workers. Nonetheless, even in a limited data-taking period, the results are very encouraging, especially as a demonstration of the sensitivity.
Within the data taking, the 21000-s period is selected because it does not present high seismic or anthropogenic noise. In Fig. 5, we show the amplitude spectral density (ASD), i.e., the square root of the power spectral density (PSD) mediated over the selected period. The integration time of each pwelch is 5200 s. It has also been checked that the result is not affected by changing the integration time of the pwelch. In Fig. 5, referring to the left-hand scale, we read the amplitude spectral noise, reported to indicate the torque residual noise τn of the measuring apparatus. In the region between about 20 mHz and 100 mHz, the spectrum is indeed compatible with thermal noise, whose equation is given by:
τ̃tn ≈ √( 4 K_B T k / (Q · 2π f) ) (1)
Here τ̃tn is the amplitude spectral density of the thermal noise, K_B is the Boltzmann constant, T is the temperature, the mechanical quality factor Q ≈ 90 measured during balance free oscillations, and k = I (2π f₀)² is the restoring constant. The lower limit is reached at about 60 mHz, and the value is 7 × 10⁻¹³ Nm/√Hz. Indeed, the amplitude spectral density τ̃ of torque still depends on environmental conditions. In particular, during the quieter night hours, the spectrum is compatible with the thermal noise spectrum while in the evening and morning hours, the noise tends to rise above this level.
Fig. 5 — Prototype sensitivity and thermal noise.
Fig. 6 — Design sensitivity and expected signal in the final Archimedes experiment.
Looking ahead to the Archimedes experiment, these results are promising. The sensitivity necessary for the final experiment is of the order of τn less than 10⁻¹³ Nm/√Hz, at the frequency region around 10 mHz. The final design sensitivity is reported in Fig. 6: the horizontal blue line is the expected signal value. We point out that the signal is not present at all frequencies, but rather the blue line represents the value that the signal will have once the single modulation frequency has been chosen. From the figure, it is seen that the design sensitivity is limited by thermal noise and seismic noise. The thermal noise is evaluated using Eq. 1 with the expected parameters for the final balance: resonance frequency f₀f = 5 mHz, moment of inertia I_f = 0.3 kg m², losses of the order of φ_f = 1/Q_f = 10⁻⁵, and working temperature T_f = 77 K. The seismic noise is assessed using the main formula that describes the coupling of the horizontal seism with the rotation of the suspended arm:
τ̃sn ≈ M_t ẍ δ (2)
where M_t is the total suspended mass, ẍ is the ground acceleration, and δ is the distance between the center of mass and the rotation point. The final balance will have a total suspended mass (arm and samples) M_t = 1 kg and an expected δ ≈ 5 µm. This value is rather conservative, because we have already demonstrated a value of δ = 15 µm in the initial prototype used during the O3 Virgo run and balance arm will be equipped for remote tuning. The seismic noise used to calculate the expected torque noise due to seism is measured in the Sos Enattos mine, and the period is the month of August 2023. The mine, although no longer used for mining, nevertheless sees the entry of miners for maintenance and safety work, except for a two-week holiday. For this reason, the estimation of noise due to the seism is reasonably conservative. In a future laboratory, access and work would be regulated according to the needs of the data taking.
The fact that the prototype has reached thermal noise is an excellent viaticum toward the final balance, in which the reduction in torque noise compared to the current thermal noise contribution is expected to be determined both by the cryogenic operation of the balance, 77 K compared to 300 K, and by the lower resonance frequency, designed to be 5 mHz. The suspension quality factor Q also needs to be much improved. The lowering of the temperature is expected to enhance it and various studies are underway within the Archimedes collaboration, which will be conducted both considering the Cu-Be joints themselves and possibly other materials with lower losses.
At frequencies below 20 mHz, the prototype is limited by ambient noise. Although the site is extremely quiet, several factors must be considered. First of all, the prototype is installed in a peripheral room of the central building, so it is particularly exposed to wind and variations in ambient temperature. Furthermore, at the moment, for contingent reasons, not all instruments that generate seismic noise (typically through cooling fans) have been removed from the scale. In the next sensitivity studies of the prototype, these instruments will be removed and an improvement in sensitivity is expected even below 20 mHz. Finally, we point out that the final balance is installed in the central part of the building, protected from environmental noise and, in the latest version, it will be installed in the underground laboratory which is planned.
4. Dark photon field and torque on the beam balance
The beam balance used in the measurement is equipped with masses of different materials. Being more sensitive to dark photons coupled with B-L current J_D, we restrict the analysis to this case. Here we use the units in which c and ε₀ are set to one and we will recover the SI at the end of the section. The Lagrangian is given, in the standard massive-vector form, by the field-strength term in F, the mass term in m_A carrying the vector field A, and a coupling term joining the B-L current J_D to the field through the coupling constant ε_D normalized to the electromagnetic coupling constant e (3)
where F is the field strength, m_A is the mass of the vector field, J_D is the B-L current, and ε_D is the coupling constant normalized to the electromagnetic coupling constant e. The dark photon field is considered nonrelativistic so that the time component A_t can be neglected with respect to A when evaluating the force on a charge q_D. Following in particular the analysis of the cited works, the vector dark matter field at location x is given by
A(t, x) = A₀ e_A cos(m_A t − k x + φ(t)) (4)
where e_A is the polarization vector. The phase factor φ(t) and the amplitude A₀ can be regarded as constant within the coherent time scale τ = 2π/(m_A v₀²) — τ of order 10⁶ s for m_A = 10⁻¹⁵ eV — and the force on the charge is the coupling constant times the charge times the time derivative of the field, which for the field above oscillates at the dark photon frequency with amplitude proportional to A₀ q_D m_A (5)
Here q_D is the B-L total charge, which is equal to the number of neutrons of the mass M. The amplitude of the field A₀ is related to the dark photon energy density ρ_DM by A₀ = √(2 ρ_DM)/m_A. By substituting and performing the mean over the direction of polarization, the standard deviation of the force along the X axis is proportional to the coupling constant times the charge q_D times the square root of the dark matter energy density ρ_DM, divided by the square root of three and by the square root of the vacuum permittivity (6)
The evaluation of torque on the balance can be performed considering that for equal aluminum and lead mass M_Al = M_Pb = M, the difference Δq_D of neutron numbers is given by
Δq_D = (M/m_b) [ (1 − Z_Pb/A_Pb) − (1 − Z_Al/A_Al) ] = 0.0863 (M/m_b) (7)
Thus, calling q = M/m_b the total number of baryons on each mass, the torque τ_q acting on the balance is the root-mean-square force of Eq. 6 multiplied by the fraction 8.6 × 10⁻², by the total baryon number q, and by the force arm L_b = 0.24 m (8)
where L_b = 0.24 m is the force arm. The factor 8.6 × 10⁻² is the fraction of force produced by the photon field which is converted in useful signal in the detector.
The limit value of ε_B−L is shown in Fig. 7. To obtain the coupling constant from the torque signal, first we perform a pwelch on the whole data set (with time length T), and we obtain the spectrum of the torque mean square deviation; we then divide the ASD by the square root of T to obtain the value of amplitude of the deviation in each frequency bin, and we multiply by 2 to obtain the 95% confidence value; finally, we invert Eq. 8 to obtain the corresponding value of the coupling constant. The simple division by the square root of T is allowed by the coherence time of the dark photon wave that is longer than the measurement time.
Fig. 7 — Limits on coupling ε_B−L of the present experiment (blue curve) and expected limits with 2 weeks (red dashed) or one year (green dashed) integration time. The horizontal lines are the present limits from EOT-WASH (red) and MICROSCOPE (black) with free fall experiments and at low frequency limits from torsion balance direct search.
Finally, in Fig. 8 the spectrogram of the correction signal over an entire night is reported. It can be appreciated again that no lines are visible and no glitches or other particular events.
Fig. 8 — Spectrogram of the correction signal, showing no lines at frequencies of interest.
5. Discussion and future developments
In this work, the sensitivity of a prototype balance was presented, useful for defining the last critical parameters of the Archimedes balance and for designing a balance for the direct search of the ultralight dark photon B-L in the mass band around 10⁻¹⁶ eV. Particularities of the balance are the interferometric reading, the closed-loop work, and the fact that it is installed in an extremely quiet site from a seismic point of view. The sensitivity of the prototype, in the tens of mHz band, is compatible with the thermal noise of the suspension. This result constitutes a first viaticum for the final Archimedes balance, which will have to achieve a torque sensitivity approximately 10 times higher, benefitting both from lowering the temperature and a necessary improvement in the quality factor of the suspension, currently under study. The prototype balance is equipped with a weight and counterweight of different materials, so as to be suitable for a direct search for the B-L dark photon. The sensitivity achieved made it possible to reach, even in a very limited run in time, a limit on the coupling close to the currently known limits and demonstrated that with a data taking of the order of months, it would be possible to undertake a direct search for dark photons with sensitivity to the best coupling of the current known limits. Motivated by these results, the next few months will be dedicated to the first scientific runs, in particular, for the direct search for the dark photon in the mass band of about a decade around 10⁻¹⁶ eV.
Acknowledgements
We are extremely grateful to Luca Loddo, Francesco Sedda, Alessandro Porcu, Mauro Porcu, Francesco Cossu, Giuseppe Lai, and Fabrizio Murgia; their generous work made ours possible. We are also in debt with Luca Francescon and Riccardo Machia for their precious support in vacuum equipment.
Funding: Open access funding provided by Università degli Studi di Napoli Federico II within the CRUI-CARE Agreement.
Data Availability Statement: This manuscript has associated data in a data repository. The data are available on the authors' laboratory repository upon reasonable request to the corresponding author.
(The 29-item reference list is omitted for length; the complete text is at the source.)
The way in
https://doi.org/10.1140/epjp/s13360-024-04920-xLICENCE. The article carries its own Creative Commons statement — ‘This article is licensed under a Creative Commons Attribution 4.0 International License’ — printed in the Open Access block of the version of record in The European Physical Journal Plus, volume 139 (2024), article 158, with open access funding provided by Università degli Studi di Napoli Federico II. The Unpaywall record for this DOI agrees: cc-by. TEXT. Reproduced below in full from the version of record. Running heads, page numbers, author affiliation numerals and reference-number markers are dropped as page furniture; the 29-item bibliography is omitted and the complete list is at the source. The eight figures are photographs, Bode plots and noise spectra that cannot be reproduced as text, so each is given as its caption, which carries the content. Displayed equations are given in plain notation with their original numbers, except the dark-photon Lagrangian (3), the oscillating force (5), the root-mean-square force (6) and the torque relation (8), which reached the library as multi-line scanned mathematics with symbols lost, and are therefore given as named results rather than guessed.
How to cite it
Annalisa Allocca, Saverio Avino, Enrico Calloni, Sergio Caprara, Massimo Carpinelli, Andrea Contu, Luca D’Onofrio, Domenico D’Urso, Rosario De Rosa, L. Errico, Marina Esposito, Gianluca Gagliardi, Marco Grilli, Valentina Mangano, Maria Marsella, Luca Naticchioni, Antonio Pasqualetti, Gianpiero Pepe, Maurizio Perciballi, Paola Puppo, Piero Rapagnani, Fulvio Ricci, Luigi Rosa, Carlo Rovelli, Davide Rozza, Paolo Ruggi, Naurang L. Saini, Valeria Sequino, Valeria Sipala, Daniela Stornaiuolo, Francesco Tafuri, Lucia Trozzo (2024) Thermal noise-limited beam balance as prototype of the Archimedes vacuum weight experiment and B-L dark photon search. doi:10.1140/epjp/s13360-024-04920-x
Where it sits in the curriculum
What the vacuum isInertia and gravity from the vacuumThe evidence ladder