The Spacetime Metric

Level 6 · Research preparation teaching kit · Doctoral and independent-research pathway

Open replication laboratory

Use the learner record during the live investigation, then use the instructor guide to facilitate comparison, address misconceptions, and assess evidence-bounded reasoning.

Learner lab record

Portable replication-package release gate

Can an independent team reproduce the apparatus state, raw-data lineage, analysis environment, and declared decision without private clarification?

Setup

Use the replication-package gate. Assemble hardware/sample identity, protocol, calibration, raw data, metadata, code, environment lock, analysis outputs, null/failed runs, and license; test the package from a clean environment.

Predict first

  1. 1. Predict which missing artifact would most likely prevent an independent rerun.
  2. 2. Declare what mismatch triggers a package hold rather than an explanatory patch.
Variables
VariableRoleUnit
Package artifactsrelease inputsfiles/records
Checksums and environment lockintegrity inputshash/version
Independent rerun resultdependentpass/hold
Discrepancy classificationadjudication outputcategory

Observation columns

artifact/gatepresentchecksum/versionindependent resultdiscrepancyownerrelease state

Analyze

  1. 1. Can raw results be regenerated from immutable inputs?
  2. 2. Are failed and null runs preserved?
  3. 3. Does the environment lock cover all analysis dependencies?
  4. 4. Can a discrepancy be localized without changing the preregistered decision?

Conclusion frame

The package passed ___ of ___ gates; independent rerun ___ at artifact ___, classified as ___, so release state is ___ pending ___.

Instructor guide · 80–120 minutes

Teach the investigation, not the interface

Learning target: Researchers turn an exploratory result into a portable, independently executable evidence package that preserves positive, null, and failed outcomes.

Prepare

  • Define the package schema and release license.
  • Provision a clean rerun environment.
  • Prepare one hidden missing dependency and one data-lineage break.

Facilitation moves

  • Do not let the original author operate the independent rerun.
  • Require immutable raw inputs and checksums.
  • Classify discrepancies before changing code or protocol.

Accessibility and participation

  • Provide a machine-readable and human-readable manifest.
  • Use explicit gate labels and remediation owners.
  • Ensure documentation is screen-reader navigable and command examples are copyable.

Evidence of learning

  • A complete immutable manifest
  • A clean-environment rerun
  • A classified discrepancy and release decision

Misconception checks

Publishing analysis code is sufficient for replication.

Hardware/sample identity, calibration, raw data, metadata, environments, decisions, and failures are also required.

A failed independent run proves misconduct or falsity.

It triggers structured discrepancy localization across protocol, apparatus, environment, data, and analysis.

Extension

Run a third-party reproduction using only the public package and publish a versioned discrepancy report.